<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-30 02-59-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 4/5, 72 dBuV NOSTALGI
Pilot RDS Phase Difference
6.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 65 kHz 6302 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,9 dBr 5,04 dBr 6,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"John Travolta & Olivia Newton-john - You're the one that i want "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 65 kHz MIN: 8 kHz % above 76 kHz: 0,0000 Acquired: 2024/07/30 2.58.50 Total samples: 6302 Equivalent time: 0:05:15 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,0 dBr MIN: 3,9 dBr AVE: 5,04 dBr % above 12,2 dBr: 0,0 Last value: 5,0 dBr (2024/07/30 2.58.50) 02.44 02.46 02.48 02.50 02.52 02.54 02.56 02.58 0 2 4 6 Pm [dBr]